Frost line depth map
Frost line depth by state
The number each state's residential building code uses, or, where the state leaves it to local building departments, the range they publish. Each state's page has the county table or the local values, the code section, and the source.
| State | Frost depth | Set by |
|---|---|---|
| Alabama | 12 inches | Set locally |
| Alaska | 42 to 120 inches, usually 42 | Set locally |
| Arizona | 12 to 30 inches, usually 12 | Set locally |
| Arkansas | 12 to 24 inches, usually 12 | Set locally |
| California | 12 to 24 inches, usually 12 | Set locally |
| Colorado | 30 to 48 inches, usually 36 | Set locally |
| Connecticut | 42 inches | Statewide |
| Delaware | 24 to 32 inches, usually 32 | Set locally |
| District of Columbia | 30 inches | Statewide |
| Florida | None (12″ footing minimum) | No frost depth |
| Georgia | 12 inches | Set locally |
| Hawaii | None (12″ footing minimum) | No frost depth |
| Idaho | 24 inches | Set locally |
| Illinois | 36 to 42 inches, usually 42 | Set locally |
| Indiana | 24 to 36 inches | By county |
| Iowa | 42 inches | Set locally |
| Kansas | 24 to 36 inches, usually 36 | Set locally |
| Kentucky | 24 to 33 inches | By zone |
| Louisiana | None (12″ footing minimum) | No frost depth |
| Maine | 48 to 60 inches, usually 48 | Set locally |
| Maryland | 18 to 36 inches, usually 30 | Set locally |
| Massachusetts | 48 inches | Statewide |
| Michigan | 42 inches | Statewide |
| Minnesota | 42 to 60 inches | By zone |
| Mississippi | None (12″ footing minimum) | No frost depth |
| Missouri | 18 to 36 inches, usually 30 | Set locally |
| Montana | 36 to 48 inches, usually 42 | Set locally |
| Nebraska | 36 to 42 inches, usually 42 | Set locally |
| Nevada | 12 to 36 inches, usually 12 | Set locally |
| New Hampshire | 48 inches | Set locally |
| New Jersey | 30 to 36 inches | By zone |
| New Mexico | 16 to 36 inches, usually 16 | Set locally |
| New York | 42 to 48 inches, usually 48 | Set locally |
| North Carolina | 12 inches | Statewide |
| North Dakota | 48 to 54 inches, usually 54 | Set locally |
| Ohio | 30 to 42 inches, usually 36 | Set locally |
| Oklahoma | 18 inches | Set locally |
| Oregon | 12 to 24 inches | By county |
| Pennsylvania | 30 to 48 inches, usually 36 | Set locally |
| Rhode Island | 40 inches | Statewide |
| South Carolina | 12 inches | Set locally |
| South Dakota | 42 inches | Set locally |
| Tennessee | 12 inches | Set locally |
| Texas | 12 to 24 inches, usually 12 | Set locally |
| Utah | 30 to 36 inches, usually 30 | Set locally |
| Vermont | 60 inches | Set locally |
| Virginia | 12 to 24 inches, usually 24 | Set locally |
| Washington | 12 to 24 inches, usually 12 | Set locally |
| West Virginia | 24 to 32 inches, usually 30 | Set locally |
| Wisconsin | 48 inches | Statewide |
| Wyoming | 34 to 54 inches, usually 36 | Set locally |
What the frost line is
The frost line, or frost depth, is how far down the ground freezes in a hard winter. Wet soil expands as it freezes and lifts anything resting in it, then lets it drop when it thaws. That's frost heave, and it's why a deck post set too shallow rises a little every winter, a fence leans, and concrete steps crack away from the house.
So building codes require footings to sit below it. The model code most states adopt, the International Residential Code, says footings must reach the frost line set by the local building official (section R403.1.4.1), and never sit less than 12 inches below undisturbed ground anywhere (R403.1.4). Each state, county or city fills in the number in its climatic and geographic design-criteria table (IRC Table R301.2, numbered R301.2(1) before the 2021 edition).
Why online "frost depth maps" don't match your building department
The maps that show deep frost across the whole northern half of the country usually come from research data: how deep the ground actually froze, or a 100-year design figure for unheated, snow-free ground. A building code number is a rule, set once for a whole town or county and often rounded to a safe, simple figure. The two can differ by a foot or more, and only the code number matters for a permit. That's why this page uses the code values and links to where each one comes from.
What has to go below it
- Deck, porch and addition footings. The bottom of the footing, measured from finished grade. The inspector checks the hole before the concrete goes in.
- Garages and other foundations. The model code exempts small detached sheds and garages (light-frame, up to 600 square feet, eaves 10 feet or lower) and decks not attached to the house, but not every town adopts those exceptions.
- Water and sewer lines. Below the frost line at least. Many water utilities set a deeper burial depth for the service line from the street.
- Fence posts. No code requires it for an ordinary fence, but posts set to the frost depth, with gravel at the bottom, don't heave and lean.
Can a footing be shallower?
Yes, with a frost-protected shallow foundation (FPSF): rigid foam insulation laid around and out from the footing keeps the ground under it from freezing, so the footing can be as shallow as about 12 to 16 inches in most of the country. It's in the model code (IRC R403.3) and common in Scandinavia, but it has to be designed for your climate, and it's rare for decks. Ask your building department before you plan on it.
Sources
- International Code Council, 2021 International Residential Code, Chapter 4 Foundations (R403.1.4, R403.1.4.1, R403.3)
- International Code Council, 2021 IRC Chapter 3, Table R301.2 Climatic and Geographic Design Criteria
- NAHB Research Center for HUD, Revised Builder's Guide to Frost Protected Shallow Foundations (2004), via the PNNL Building America Solution Center